ELEKTROFYZIOLOGICKÉ NÁLEZY PO BILATERÁLNÍ THORAKOSKOPICKÉ ABLACI FIBRILACE SÍNÍ (ELECTROPHYSIOLOGICAL FINDINGS AFTER BILATERAL THORACOSCOPIC ATRIAL FIBRILLATION ABLATION USING IRRIGATED BIPOLAR RADIOFREQUENCY ENERGY)

T. Skála, V. Černíček, O. Moravec, P. Šantavý, A. Steriovsky, M. Táborský (Olomouc, Zlín)
Topic: a general field
Type: Presentation - doctors, XVIII. české a slovenské sympozium o arytmiích a KS

Background: Thoracoscopic atrial fibrillation ablation (TARAFS) using irrigated bipolar radiofrequency energy (Medtronic Cardioblate Gemini -S) should result in wide isolation of the pulmonary veins (PVs) and posterior left atrial (LA) wall (the box-lesion technique). Electrophysiological findings after this technique using this instrumentation are not known.


Methods and results: 22 patients with AF recurrence after bilateral TARAFS for persistent AF had a radiofrequency catheter ablation (CA) at least three months after TARAFS.

Results: Out of 22 patients, the box lesion was not completed in 15 (68.2 %) patients. 12 had no endocardial signs of any prior ablation, 2 had right pulmonary PVs isolated and 1 had left PVs isolated. At the end of CA, box lesion was finished in all 15 patients and AF non-inducibility was achieved in 18 patients. 19 patients (86.4 %) were free of any atrial tachyarrhythmia with/without AADs and with/without repeated ablation (1.18 ablation/patient).


Conclusion: In a considerable number of patients with AF recurrence after TARAFS box lesion is not finished and no signs of prior ablation to guide a touch-up catheter ablation are found on electroanatomical voltage map. In majority of patients, additional ablation beside box lesion is needed to achieve AF non-inducibility.